No. of outputs:
4
No. of outputs:
2
Wave shape: 
Compensated rectangular
Wave shape: 
Compensated rectangular
Width of impulses:
200µSec
Width of impulses:
100-250mSec
No. of programs:
3
No. of programs:
1
Current intensity:
 
70 mA (peak on impulse, load 1K_)
Current intensity:
 
32 mA (peak on impulse, load 1K_)
Voltate supply:


1 rechargeable battery pack
Ni-Mh 4,8V-1.000 mA/h (code VATW09)

Voltate supply:


4,8V-4 rechargeable batteries Ni-Mh - 2/3 AAA- 1,2V- 270 mA/h (code VATW10)

Consumption:
0,3-0,7W (min-max)
Consumption:
0,4W (max)
Dimensions:
118x124xh1=49xh2=25 mm
Dimensions:
120 x 49 x 39mm
Weight:
290g
Weight:
120g
Marking:
Marking:



Twin-Up Body Face is safe and complies with the most stringent international regulations. It is entirely designed and manufactured by Vupiesse Italia, a company with a Certified Quality System in conformity with EN ISO 9001:2000 and EN ISO 13485:2000, issued by the German institutes TÜV-CERT and TÜV RHEINLAND. The company has considerable experience in the manufacture of professional electro-medical equipment, used mainly by the major hospitals and centres that deal with sports medicine, physiotherapy and beauty medicine.


• During the menstrual period, skin conduction changes; stimulation could prove less comfortable.
• Stimulation causes reddening of the skin where the electrodes are placed, especially in the case of persons with sensitive skin. Such reddening is perfectly normal and usually disappears quickly.
• In case of allergy to the electrode gel, suspend treatment and see a doctor.
• Do not apply the electrodes to areas with hyperpigmentation (moles) or varicose veins.
• Do not apply the electrodes directly to the breasts, but to the muscles which support them.
• Do not use in intimate areas, under the armpits, in the groin or behind the knees.
• Do not use on the abdomen of expectant mothers.
• Do not use TwinUp Body Face on children, people with pace-makers or those in poor psychophysical conditions or with physiological or organic disorders.
• The appliance is not suited for wearers of metal prostheses or aortoabdominal bypasses.
• Do not apply in transthoracic mode to prevent interference with heart frequency and, in general, only use on facial muscles.

IN CASE OF DOUBT, SEE A DOCTOR.



© Copyright 2003 Vupiesse Italia S.r.l. - All rights reserved - Disclaimer